5.7.3.12.5. Examples
The below configuration is allowing 3000msec Delay Signal Duration to
outgoing calls.
voice-port 1/0
timing delay-dulation 3000
5.7.3.13. timing delay-start (E&M Voice Port Command)
To set min. Delay time between Outgoing Seizure to Out-Dial Address, use
timing delay-start command. To apply the default value, use no command.
timing delay-start milliseconds
no timing delay-start
5.7.3.13.1. Syntax
Keyword / Argument Description
milliseconds Set min. Delay time from Outgoing Seizure to Outdial
Address.
Unit: milliseconds.
The acceptable values are” 20~2000”
5.7.3.13.2. Default Value
300 milliseconds
5.7.3.13.3. Command Mode
Voice-port Configuration Mode
5.7.3.13.4. Usage Guideline
timing delay-start command sets Minimum Delay time to outing calls.