PassFinder AP2520 VoIP Router/Gateway Operation Manual Version 1.10 / Mar. 2002
AddPac Technology Co., Ltd. -
204 -
6
timing delay-start milliseconds
Specify the minimum delay time from outgoing
seizure to outdial address. Valid entries for
delay-start are from 20 to 2000 milliseconds.
7
timing wink-duration
milliseconds
Specify the maximum wink signal duration. Valid
entries for wink-duration are from 100 to 400
milliseconds.
8
timing wink-wait milliseconds
Specify the maximum wink-wait duration for a
wink start signal. Valid entries for wink-wait are
from 100 to 5000 milliseconds.
9
timing dialout-delay
milliseconds
Sends the number to the E&M trunk or
designates dial-out delay for cut-through.
Values between 100 ~ 5000 msec can be used.
10
timing wait-wink milliseconds Designates the maximum wait value for the wink
signal.
Values between 100 ~ 5000 msec can be used.